2. Basic Commands
bit5 gives an in dication on wheth er the projector can be (re)started or not (hot restrike), if the cool down cycle
is active (bit5 = 0) the projector can not be restarted until the cool dow n cycle has been completed.
Example
Read the status being : \x23:
•projectorisON
textbox is on
cool down cycle is inactive
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x67
Checksum
\x68
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x67
Data[0]
\x23
Checksum
\x8b
Stop
\xff
2.6 Lens commands
2.6.1 Lens shift
Description
Shifts the lens down or up depending on t
he data sent.
Command
Command [0]
\xf4
Command [1]
\x81